Schistosoma (IgG) AB, FMI
Schistosoma Species Antibody, IgG, Serum
Test Codes
EPIC: LAB1232158, Beaker: Schistosoma, Quest: 34306
Department
Send Outs
Specimen Collection Criteria
Collect (preferred specimen): One Gold-top SST tube.
Also acceptable: One plain Red-top tube.
Physician Office/Draw Specimen Preparation
Let specimen clot 30-60 minutes then centrifuge to separate serum from cells. Transfer serum to a plastic transport tube and refrigerate (2-8°C or 36-46°F).
Preparation for Courier Transport
Transport: 1.0 mL serum, refrigerated (2-8°C or 36-46°F). (Minimum: 0.5 mL)
Rejection Criteria
Specimens not collected and processed as indicated.
In-Lab Processing
Let specimen clot 30-60 minutes then centrifuge to separate serum from cells. Transfer serum to a plastic transport tube and refrigerate (2-8°C or 36-46°F).
Transport: 1.0 mL serum, refrigerated (2-8°C or 36-46°F). (Minimum: 0.25 mL)
Storage
Specimen Stability for Testing:
Room Temperature (20-26°C or 68-78.8°F): 7 days
Refrigerated (2-8°C or 36-46°F): 14 days
Frozen (-20°C/-4°F or below): 1 month
Specimen Storage in Department Prior to Disposal:
Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.
Laboratory
Sent to Quest Diagnostics, Wood Dale, IL.
Performed
Wednesday, Saturday.
Results available in 2-5 days.
Reference Range
<1.00
Test Methodology
Fluorescent Microsphere Immunoassay
Interpretation
| <1.00 | Antibody not detected |
| ≥1.00 | Antibody detected |
This assay utilizes the microsomal fraction of
adult
S. mansoni worms (MAMA) as antigen and is thus highly
specific (99%) and sensitive (96%) for detection of infection caused by
S.
mansoni. Although the assay is also highly specific for infections caused
by other Schistosoma species
(S. japonicum, S. haematobium, S. mekongi),
its sensitivity for these infections is lower (55%). Antibody levels do not
correlate with intensity of infection.
Clinical Utility
This assay aids in the diagnosis of schistosomiasis.
CPT Codes
86682
Contacts
Send Outs Laboratory – RO
248-551-9045
Name: Send Outs Laboratory – RO
Location:
Phone: 248-551-9045
Last Updated
12/19/2025
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.