Cadmium, Blood
Test Codes
EPIC: LAB1232150, Beaker: Cadmium, Quest: 299
Department
Send Outs
Instructions
High concentrations of gadolinium and iodine are known to interfere with most metal tests. If either gadolinium- or iodine-containing contrast media has been administered, a specimen should not be collected for 96 hours.
Specimen Collection Criteria
Collect: One Royal Blue-top EDTA tube.
Physician Office/Draw Specimen Preparation
Do not centrifuge. Maintain refrigerated at (2-8°C or 36-46) prior to transport.
Preparation for Courier Transport
Transport: 4.0 mL whole blood, refrigerated at (2-8°C or 36-46). (Minimum: 2.0 mL)
Rejection Criteria
- Clotted specimens.
- Specimens not collected and processed as indicated.
In-Lab Processing
Do not centrifuge. Maintain refrigerated at (2-8°C or 36-46) prior to transport.
Transport: 4.0 mL whole blood, refrigerated at (2-8°C or 36-46). (Minimum: 2.0 mL)
Storage
Specimen Stability for Testing:
Room Temperature (20-26°C or 68-78.8°F): 14 days
Refrigerated (2-8°C or 36-46°F): 14 days
Frozen (-20°C/-4°F or below): 14 days
Specimen Storage in Department Prior to Disposal:
Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.
Laboratory
Sent to Quest Diagnostics, Wood Dale, IL.
Performed
Monday – Friday.
Results available within 2 days.
Reference Range
| Adults, Non-Smokers | ≤1.7 mcg/L |
| Adults, Smokers | ≤5.0 mcg/L |
| OSHA Reference Range | ≤5.0 mcg/L |
| Toxic Concentration | Early signs of toxicity have been observed at 30 mcg/L |
Test Methodology
Inductively Coupled Plasma/Mass Spectrometry
Interpretation
See report.
Clinical Utility
Cadmium, Blood - Cadmium is
a naturally occurring element that is mined and used in industrial production
because of its durability. Excessive cadmium exposure can damage lungs,
kidneys, and the digestive tract.
CPT Codes
82300
LOINC: 77307-7
Contacts
Send Outs Laboratory – RO
248-551-9045
Name: Send Outs Laboratory – RO
Location:
Phone: 248-551-9045
Last Updated
12/17/2025
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.