A niger IgE
Aspergillus niger Mold Panel, Aspergillus niger (Allergen Specific IgE)
    Test Codes
    EPIC: LAB703,  Beaker: EASN, Antrim #31715
    Department
    Immunology
    Specimen Collection Criteria
    Collect: One Gold-top SST tube.
Twenty individual allergen assays or allergen screens can be performed on one 5.0 mL Gold-top SST tube. Each allergen assay requires 100.0 mcL of serum.
    Physician Office/Draw Specimen Preparation
    Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Refrigerate (2-8°C or 36-46°F) the centrifuged collection tube within two hours of collection.
    Preparation for Courier Transport
    Transport: Centrifuged collection tube, refrigerated (2-8°C or 36-46°F).
    Rejection Criteria
    - Plasma specimens. 
- Severely lipemic or hemolyzed specimens. 
In-Lab Processing
    Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Room temperature is acceptable for a maximum of two hours.
    Storage
    Specimen Stability for Testing:
Centrifuged SST Tubes and Microtainers® with Separator Gel
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): Unacceptable
Red-top Tubes and Microtainers® without Separator Gel
Room Temperature (20-25°C or 68-77°F): 2 hours
Refrigerated (2-8°C or 36-46°F): Unacceptable
Frozen (-20°C/-4°F or below): Unacceptable
Serum Specimens (Pour-Overs)
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 1 month
Specimen Storage in Department Prior to Disposal:
Refrigerated (2-8°C or 36-46°F): 7 days
    Laboratory
    Royal Oak Special Chemistry Laboratory
    Performed
    Monday – Friday.
Results available the next business day.
    Reference Range
    Allergy Reference Range: Less than 0.35 kU/L. 
    
        
            | Range (kU/L) | Class | Interpretation | 
        
            | Less than or equal to 0.34 | 0 | Negative | 
        
            | 0.35-0.69 | 1 | Low | 
        
            | 0.70-3.49 | 2 | Medium | 
        
            | 3.50-17.49 | 3 | High | 
        
            | 17.50-49.99 | 4 | Very High | 
        
            | 50.0-100.0 | 5 | Very High | 
        
            | Greater than 100 | 6 | Very High | 
    
    Test Methodology
    Fluorescence Enzyme Immunoassay (FEIA).
    Interpretation
    The allergen class may not be predictive of clinical disease in some patients. The diagnosis of allergy should be based upon patient history and clinical findings. The diagnosis of allergy should not be based upon laboratory findings alone.
    Clinical Utility
    A positive test result (class 1 or greater) is indicative of the presence of allergen-specific IgE and suggests an increased likelihood of allergic disease.
    CPT Codes
    86003
LOINC: 6830-4
    Contacts
    
        
             Special Chemistry Laboratory – RO 
              
             248-551-8044 
         
        
            Name:  Special Chemistry Laboratory – RO 
            Location:   
            Phone:  248-551-8044 
         
    Last Updated
    6/5/2025
    Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company. 
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.