Aspergillus fumigatus IgG
Aspergillus fumigatus, Aspergillus fumigatus (Allergen Specific IgE), EASF
Test Codes
Order Reference Lab Miscellaneous Send Out:
EPIC: LAB848, Beaker: Ref. Lab. Misc., Viracor: 75220
Department
Send Outs
Specimen Collection Criteria
Collect: One Gold-top SST tube.
Physician Office/Draw Specimen Preparation
Let specimen clot 30-60 minutes then centrifuge
to separate serum from cells. Transfer serum to plastic transport tube and
maintain at room temperature (20-26°C or 68-78.8°F) prior to transport.
Preparation for Courier Transport
Transport: 0.5 mL serum, room temperature (20-26°C or 68-78.8°F). (Minimum: 0.15 mL)
Rejection Criteria
- Severely lipemic or hemolyzed specimens.
- Specimens not collected and processed as indicated.
In-Lab Processing
Let specimen clot 30-60 minutes then centrifuge to separate serum from cells. Transfer serum to plastic transport tube and maintain at room temperature (20-26°C or 68-78.8°F) prior to transport.
Transport: 0.5 mL serum, room temperature (20-26°C or 68-78.8°F). (Minimum: 0.15 mL)
Storage
Specimen Stability for Testing:
Room Temperature (20-26°C or 68-78.8°F): 7 days
Refrigerated (2-8°C or 36-46°F): 30 days
Frozen (-20°C/-4°F or below): 30 days
Specimen Storage in Department Prior to Disposal:
Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.
Laboratory
Sent to Quest Diagnostics, Wood Dale, IL.
Performed
Monday – Friday.
Results available in 3 days.
Reference Range
1 - 100 mg/L
Test Methodology
Fluorescence Enzyme Immunoassay (FEIA)
Clinical Utility
Although there have been many publications concerning the measurement of allergen-specific IgG, the clinical utility of such tests has not been established except in special situations. Thus, the quantitative IgG test should only be ordered by specialists who recognize the limitations of the test. The normal reference ranges reported represent the expected results for individuals who have no unusual exposure and have not been immunized with the indicated allergen. The ranges reported have no disease-associated significance.
CPT Codes
86001
Contacts
Send Outs Laboratory – RO
248-551-9045
Name: Send Outs Laboratory – RO
Location:
Phone: 248-551-9045
Last Updated
9/24/2026
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.