17-Hydroxypregnenolone
Hydroxypregnenolone, 17-, Pregnenolone, 17-OH-
Test Codes
EPIC: LAB1231616, Beaker: 17-Hydrox S, Quest: 8352
Department
Send Outs
Specimen Collection Criteria
Collect (preferred specimen): One plain Red-top tube.
Unacceptable: Gold-top Serum Separator Tube (SST).
Physician Office/Draw Specimen Preparation
Let specimen clot 30-60 minutes then centrifuge to separate serum from cells. Transfer serum to a plastic transport tube and refrigerate at (2-8°C or 36-46) prior to transport.
Preparation for Courier Transport
Transport: 2.0 mL serum, refrigerated (2-8°C or 36-46) prior to transport. (Minimum: 0.4 mL)
Rejection Criteria
- Gross hemolysis.
- Grossly lipemic.
- Grossly icteric.
- Serum separator tube (SST).
- Received at room temperature.
- Specimens not collected and processed as indicated.
In-Lab Processing
Let specimen clot 30-60 minutes then centrifuge to separate serum from cells. Transfer serum to a plastic transport tube and refrigerate at (2-8°C or 36-46) prior to transport..
Transport: 2.0 mL serum, refrigerated (2-8°C or 36-46). (Minimum: 0.4 mL)
Storage
Specimen Stability for Testing:
Room Temperature (20-26°C or 68-78.8°F): 24 hours
Refrigerated (2-8°C or 36-46°F): 5 days
Frozen (-20°C/-4°F or below): 28 days
Specimen Storage in Department Prior to Disposal: 14 days
Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.
Laboratory
Sent to Quest Diagnostics, Wood Dale, IL.
Performed
Sunday – Friday.
Results available in 2-5 days.
Reference Range
By report.
Test Methodology
Chromatography/Mass Spectrometry.
Interpretation
Reference Range(s):
Adult Females, Pre-Menopausal:
| Mid Follicular | 38-378 ng/dL |
| Surge | 33-583 ng/dL |
| Mid Luteal | 70-470 ng/dL |
Pediatric Male and Female:
| <30 days | ≤3013 ng/dL |
| 1-11 months | ≤869 ng/dL |
| 1 year | ≤557 ng/dL |
| 2 years | ≤487 ng/dL |
| 3 years | ≤541 ng/dL |
| 4 years | ≤561 ng/dL |
| 5 years | ≤564 ng/dL |
| 6 years | ≤561 ng/dL |
| 7 years | ≤549 ng/dL |
| 8 years | ≤569 ng/dL |
| 9 years | ≤590 ng/dL |
| 10 years | ≤594 ng/dL |
| 11 years | ≤629 ng/dL |
| 12 years | ≤666 ng/dL |
| 13 years | ≤678 ng/dL |
| 14 years | ≤706 ng/dL |
| 15 years | ≤735 ng/dL |
| 16 years | ≤739 ng/dL |
| 17 years | ≤756 ng/dL |
Clinical Utility
17-Hydroxypregnenolone is
useful in the diagnosis of 3-Beta-Hydroxylase enzyme deficiency, a rare cause
of congenital adrenal hyperplasia, and 17-Hydroxylase (P450c17) enzyme
deficiency.
CPT Codes
84143
Contacts
Send Outs Laboratory – RO
248-551-9045
Name: Send Outs Laboratory – RO
Location:
Phone: 248-551-9045
Last Updated
12/17/2025
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.