Phencyclidine Confirmation (PCP), Urine

Urine Phencyclidine Screen, PCP, Angel dust, Phencyclidine Screen, Urine

Test Codes

Antrim: 17079, EPIC: LAB7015, SOFT: PCP9

Department

Toxicology

Specimen Collection Criteria

Collect: 50 mL random urine in a screw-capped container (preferred) or other sterile collection cup. (Minimum: 30 mL)

  • Refrigerate the specimen immediately after collection.
  • Record the exact time of specimen collection on the container or in the computer system.

Physician Office/Draw Specimen Preparation

Maintain specimen refrigerated (2-8°C or 36-46°F) prior to transport.

Preparation for Courier Transport

Transport: 50 mL urine, refrigerated (2-8°C or 36-46°F). (Minimum: 30 mL)

Rejection Criteria

  • Specimens not collected and processed as indicated.
  • Urine Vacutainer® tubes. Urine received in a glass or plastic tube with a rubber stopper may contain insufficient sample volume, preclude confirmatory testing, and give rise to contaminants and artifacts.

In-Lab Processing

Analyze urine specimen immediately upon receipt in the Laboratory.

Storage

Specimen Stability for Testing:

Room Temperature (20-26°C or 68-78.8°F): 72 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 3 months

Specimen Storage in Department Prior to Disposal:

Frozen (-20°C/-4°F or below): 2 months

Laboratory

Canton Laboratory
Dearborn Chemistry Laboratory
Farmington Hills Toxicology Laboratory
Grosse Pointe Laboratory
Lenox Toxicology Laboratory
Livonia Toxicology Laboratory
Royal Oak Automated Chemistry Laboratory
Royal Oak Toxicology Laboratory
Taylor Chemistry Laboratory
Trenton Chemistry Laboratory
Troy Chemistry Laboratory
Wayne Chemistry Laboratory

NOTE: Screens are performed at Canton, Dearborn, Farmington Hills, Grosse Pointe, Royal Oak, Taylor, Trenton, Troy, and Wayne. All confirmations are performed at Royal Oak. 

Performed

Sunday – Saturday, 24 hours a day. 

STAT screen results available within 1 hour of receipt in the Laboratory, and confirmation within 12 hours.

Routine results available within 24 hours.

Reference Range

None Detected (Positive Cutoff: 25 ng/mL).

Test Methodology

Screen: Fluorescence Polarization Immunoassay (FPIA).
Confirmation: Gas Liquid Chromatography/Mass Spectrometer (GC/MS).

The confirmation component of this test was developed by Beaumont Health. It has not been cleared or approved by the FDA. The laboratory is regulated under CLIA as qualified to perform high-complexity testing. This test is used for clinical purposes and should not be regarded as investigational or for research.

Interpretation

The confirmation component of this test was developed by Beaumont Health. It has not been cleared or approved by the FDA. The laboratory is regulated under CLIA as qualified to perform high-complexity testing. This test is used for clinical purposes and should not be regarded as investigational or for research.

Clinical Utility

Phencyclidine (PCP) is a drug of abuse. PCP acts as a stimulant, depressant, hallucinogenic and analgesic. It can be self-administered by smoking, nasal insufflation, intravenous injection or by oral ingestion. This assay is used to aid in the diagnosis and treatment of phencyclidine use or abuse. It provides a preliminary analytical result. Positive results are confirmed by chromatographic methods.

CPT Codes

80307, 80375 (alternate: G0479, G0480).
LOINC: 19659-2, 8236-2

Contacts

Last Updated

10/3/2023

Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.