Specimen Recommendations:

  • There is diurnal variation of P1NP levels, with the values being higher at night.
  • When serial measurements of P1NP are performed, specimens should be collected at the same time of the day.
  • Fasting versus fed state may also cause variation in results. Therefore, fasting sample is recommended.
  • P1NP is metabolized in the liver. In individuals with severe liver disease, clearance from the circulation might be affected resulting in elevated P1NP levels.

Specimen Collection Criteria

Collect: One Gold top tube (SST).

Also acceptable: One plain Red-top tube.

Physician Office/Draw Specimen Preparation

Let specimen clot 30 minutes. Centrifuge specimen to separate serum from cells within one hour of collection. Transfer serum to a plastic transport tube and freeze (-20°C/-4°F or below) prior to transport.

Preparation for Courier Transport

Transport: 3.0 mL serum, frozen (-20°C/-4°F or below). (Minimum: 1.5 mL)

In-Lab Processing

Let specimen clot 30 minutes. Centrifuge specimen to separate serum from cells within one hour of collection. Transfer serum to a plastic transport tube and freeze (-20°C/-4°F or below) prior to transport.

Transport: 3.0 mL serum, frozen (-20°C/-4°F or below). (Minimum: 1.5 mL)

Storage

Specimen Stability for Testing:

Room Temperature (20-26°C or 68-78.8°F): 8 hours
Refrigerated (2-8°C or 36-46°F): 24 hours
Frozen (-20°C/-4°F or below): 7 days

Specimen Storage in Department Prior to Disposal: 7 days

Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.

Laboratory

Sent to Corewell Health Reference Laboratory, Grand Rapids, MI.

Performed

Monday, Wednesday, Friday.
Results available in 2-3 days.

Reference Range

23 mcg/L to 83 mcg/L

Test Methodology

Chemiluminescence

Clinical Utility

The amino-terminal propeptide of type 1 procollagen (P1NP) is probably the most specific and sensitive marker for monitoring the efficacy of osteoporosis therapy with anabolic agents, but it is also one of the best bone turnover markers for monitoring the efficacy of antiresorptive therapy.