Procollagen type 1 N-terminal Propeptide, (P1NP)
P1NP, Procollagen peptide, P1NP intact
Test Codes
EPIC: LAB1230524, Beaker: P1NP, CHW: LAB1230524
Department
Send Outs
Instructions
Specimen Recommendations:
- There is diurnal variation of P1NP levels, with the values being higher at night.
- When serial measurements of P1NP are performed, specimens should be collected at the same time of the day.
- Fasting versus fed state may also cause variation in results. Therefore, fasting sample is recommended.
- P1NP is metabolized in the liver. In individuals with severe liver disease, clearance from the circulation might be affected resulting in elevated P1NP levels.
Specimen Collection Criteria
Collect: One Gold top tube (SST).
Also acceptable: One plain Red-top tube.
Physician Office/Draw Specimen Preparation
Let specimen clot 30 minutes. Centrifuge specimen to separate serum from cells within one hour of collection. Transfer serum to a plastic transport tube and freeze (-20°C/-4°F or below) prior to transport.
Preparation for Courier Transport
Transport: 3.0 mL serum, frozen (-20°C/-4°F or below). (Minimum: 1.5 mL)
In-Lab Processing
Let specimen clot 30 minutes. Centrifuge specimen to separate serum from cells within one hour of collection. Transfer serum to a plastic transport tube and freeze (-20°C/-4°F or below) prior to transport.
Transport: 3.0 mL serum, frozen (-20°C/-4°F or below). (Minimum: 1.5 mL)
Storage
Specimen Stability for Testing:
Room Temperature (20-26°C or 68-78.8°F): 8 hours
Refrigerated (2-8°C or 36-46°F): 24 hours
Frozen (-20°C/-4°F or below): 7 days
Specimen Storage in Department Prior to Disposal: 7 days
Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.
Laboratory
Sent to Corewell Health Reference Laboratory,
Grand Rapids, MI.
Performed
Monday, Wednesday, Friday.
Results available in 2-3 days.
Reference Range
Test Methodology
Clinical Utility
The amino-terminal propeptide of type 1
procollagen (P1NP) is probably the most specific and sensitive marker for
monitoring the efficacy of osteoporosis therapy with anabolic agents, but it is
also one of the best bone turnover markers for monitoring the efficacy of
antiresorptive therapy.
CPT Codes
835520
Contacts
Send Outs Laboratory – RO
248-551-9045
Name: Send Outs Laboratory – RO
Location:
Phone: 248-551-9045
Last Updated
4/29/2026
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.