Lab Test

Poliovirus Antibodies

Test Codes

ARUP #2014107, EPIC: LAB6130, SOFT: XPOLI

Specimen Collection Criteria

Collect (preferred specimen): One Gold-top SST tube.
Also acceptable: One plain Red-top tube.

Physician Office/Draw Specimen Preparation

Let specimen clot 30-60 minutes then centrifuge to separate serum from cells within two hours of collection. Transfer serum to a plastic transport tube and refrigerate (2-8°C or 36-46°F).

Preparation for Courier Transport

Transport: 1.0 mL serum, refrigerated (2-8°C or 36-46°F). (Minimum: 0.2 mL)

Rejection Criteria

  • Hemolyzed specimens.
  • Severely lipemic specimens.
  • Specimens not collected and processed as indicated.

In-Lab Processing

Let specimen clot 30-60 minutes then centrifuge to separate serum from cells within two hours of collection. Transfer serum to a plastic transport tube and refrigerate (2-8°C or 36-46°F).

Transport: 1.0 mL serum, refrigerated (2-8°C or 36-46°F). (Minimum: 0.2 mL)

Storage

Specimen Stability for Testing:

Room Temperature (20-26°C or 68-78.8°F): 48 hours
Refrigerated (2-8°C or 36-46°F): 14 days
Frozen (-20°C/-4°F or below): 1 year

Specimen Storage in Department Prior to Disposal:

Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.

Laboratory

Sent to ARUP Laboratories, Salt Lake City, UT.

Performed

Monday – Friday.
Results available in 7-10 days.

Reference Range

Less than 1:10: No detectable antibodies.
1:10 or Greater: Antibody to Poliovirus detected, which may represent prior immunization or current or past infection.

Reference interval applies to Poliovirus Antibody Types 1 and 3. 

Test Methodology

Semi-Quantitative Serum Neutralization.

Interpretation

The presence of Poliovirus antibodies may represent prior immunization or acute infection. The clinical significance of and the criteria for interpretation of results may require consultation with an Infectious Diseases Specialist.

CPT Codes

86658x2.

Contacts

Last Updated

3/31/2020

Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.

 

This directory currently reflects information only for specimens collected and/or processed at the
Farmington Hills, Grosse Pointe, Royal Oak, and Troy campuses.